MITSUBISHI KAKOKI KAISHA,LTD.
Products Information

Japan Gas Association Prize Winners  LNG Satellite Stations

LNG Satellite Stations

Name. Byname. Abbreviation

LNG satellite station, LNG satellite station for city gas generation, industrial LNG satellite station

General Description

MKK designs and constructs LNG (Liquefied Natural Gas) satellite stations incorporating the latest vaporization technologies, in addition to closed-circulation LNG vaporization systems (2001 Japan Gas Association engineering prize winner) and MKK type calorific control systems (1999 Japan Gas Association engineering prize winner).

Features

Closed-circulation vaporization system
¦ÂClosed structure prevents emission of chill-induced white smoke.
¦ÂContinuous round-the-clock operation is possible.
¦ÂStand-by and hot-water vaporizing equipment are not required.
¦ÂSwitching of vaporizing equipment and de-icing are not required.
¦ÂLow running cost
¦ÂAtmospheric heat is used as the heat source for circulating air.
¦ÂConversion from existing LNG vaporizing equipment is possible.

LPG-NG calorific control system
¦ÂLow cost, space saving
¦ÂNatural gas and LPG (Liquefied Petroleum Gas) are mixed and heated in one unit.
¦ÂNG heater is not required.
¦ÂLow-level heat source (15?20¡ëC) is effectively used.
¦ÂPressure loss is limited.
¦ÂLarge tolerance for load fluctuations

Process Flow

LNG Process Flow

Uses and Suggestions

¦ÂCity gas generation
¦ÂIndustrial use

Supply Data

Customer Capacity (Ton/h) Year Delivered Vaporizing Unit
A company 0.42 x 4 1984 Air type
A company 1.26 x 2 1984 Air type
B company 1.0 x 3 1985 Air + hot water type
B company 2.0 x 2 1986 Air + hot water type
C company 1.5 x 4 1994 Air type
D company 1.2 x 4 1997 Air type
E company 1.0 x 5 2000 Closed-circulation air type
F company 1.0 x 6 2000 Closed-circulation air type

Terminology

¦ÂSatellite station : City gas generation plant with small-scale LNG storage and vaporizing equipment for regasification. LNG is trucked to the satellite station from a large-scale LNG station.
¦ÂCalorific control system : System used to mix LNG and LPG per calorie of city gas (13A: 11,000 kcal/NM3).
For inquiries about the contents of this page, please contact
Industrial System Sales Department I

TEL 81-44-246-7350 / FAX 81-44-246-7352
to This Page's top